PRODUCT DETAILS

TDC 584 - IPA Conditioning Cabinet for testing Air Filters acc. to ISO 16890-4

TDC 584 - IPA Conditioning Cabinet for testing Air Filters acc. to ISO 16890-4

The harmonization of international testing standard ISO 16890-4 requires neutralization of tested filter element by Iso-propyl-alcohole (IPA) treatment. Therefore a suitable test cabinet for filter discharging is needed.

The solution proposed in ISO 16890-4, chapter 7 requires a large amount of hazardous substance with approximately 1 l of liquid IPA, whereas particularly the handling of the trays filled with liquid IPA is risky.

Advantages
  • Fast and constant saturation of the air with IPA in a customizable saturation time
  • Integrated suction and flushing of the chamber
  • Minimal use of IPA (250ml per filter)
  • Certification of security level by accredited certification bodies
Applications
  • Conditioning of air filters according to ISO 16890-4 (for followed testing of the mechanical separation behaviour with the General Air Filter Test System ALF 114)
  • Electrical neutralization of bag- and cartridge filters, filter bags and flat media

PTek, located at Hyderabad, is engaged in offering best equipment and services to the industry and research institutes in the field of Air Filter Testing, Aerosol generation, Semiconductor Process Equipment & Cryogenic systems.